A first-class construction engineering manufacturer tells you: for first- and second-class welds that are required by the design to be fully penetrated, ultrasonic testing shall be used to inspect internal defects. When ultrasonic testing cannot determine the defects, radiographic testing shall be used. The classification of internal defects and the testing methods shall comply with the provisions of the current national standards “Method for Manual Ultrasonic Testing of Steel Welds and Classification Method for Testing Results” GB11345 or “Radiography of Fusion-Welded Butt Joints in Steel and Quality Classification” GB3323. For welds of welded spherical node space frames, welds of bolted spherical node space frames, and intersecting-line welds of circular tube T-, K-, and Y-shaped joints, the classification of internal defects and the testing methods shall respectively comply with the provisions of the current national standards “Method for Ultrasonic Testing of Welds of Welded Spherical Node Steel Space Frames and Quality Classification Method,” “Method for Ultrasonic Testing of Welds of Bolted Spherical Node Steel Space Frames and Quality Classification Method,” and “Technical Specification for Welding of Building Steel Structures.”